{"title":"Modular DryRoom","description":"","products":[{"product_id":"ampcera®-mobile-modular-dry-room-for-battery-r-d-and-pilot-development","title":"[EQ] Modular Dry Room for Battery R\u0026D and Pilot Development","description":"\u003ch2\u003eAmpcera® Mobile Modular Dry Room for Battery R\u0026amp;D and Pilot Development\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eTo better serve you, we would like to discuss your specific requirement.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003ePlease \u003ca href=\"https:\/\/www.ampcera.com\/pages\/contact\" target=\"_blank\" rel=\"noopener\"\u003econtact us\u003c\/a\u003e for quote.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eIntroductions:\u003c\/h3\u003e\n\u003cp\u003eAmpcera® Mobile Modular Dry Room is a cutting-edge solution designed for industries requiring precise environmental control, such as \u003cstrong\u003esolid-state batteries, Lithium Metal Batteries, lithium-ion batteries, medical applications, food industry or other applications that require dry environment\u003c\/strong\u003e. \u003c\/p\u003e\n\u003cp\u003eThe experimental chamber consists of two modules: a dry working chamber and an equipment chamber. The dry working chamber is equipped with features such as viewing windows, Wi-Fi, smoke detectors, and standard chilling water, electricity, and gas interfaces, ensuring both comfort and safety for operators. Compared to traditional drying rooms, the low dew points experimental chamber offers advantages such as easy and quick installation, plug-and-play functionality, and low energy consumption.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Mobile Modular Dry Room offers a comprehensive, efficient, and safe solution for industries requiring controlled environments. Its innovative design, advanced features, and cost-saving benefits make it the perfect choice for businesses of all sizes. Contact us\u003cspan\u003e \u003c\/span\u003etoday to learn more and make your purchase!\u003c\/p\u003e\n\u003ch3\u003eKey Features and Benefits:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cstrong\u003eExceptional Dew Point Control:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eAchieve a dew point as low as -60°C, or \u0026lt;-50°C with single operator inside ensuring optimal performance for even the most demanding applications.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cstrong\u003ePlug-and-Play Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eReady to use with no assembly required. All essential components, such as power cables, gas lines, and (optionally) water lines for chillers, are built-in for seamless operation.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cstrong\u003eIntegrated Equipment Room:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes all necessary equipment for operation, reducing setup time and complexity.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cstrong\u003eEquipment Entrance Door:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFull swing Room-End door to allow big equipment in. with ramp, you can roll equipment in. \u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cstrong\u003eVersatile Power Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard Designed include 480V\/60Hz US standard power main supply, with customization control panel that distribute power needed for equipment requirement, customizable to meet international voltage standards.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cstrong\u003eEnergy Efficiency:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eDouble layer insulation for gas sealing allowing idle mode without leaking, Quick start-up time to reach dew point, Estimated power consumption for the equipment room to operate the standard size dry room is only 50kW, low operational costs. \u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cstrong\u003eAdvanced Chamber Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures three chambers—two-section antechambers (with dust blower section) and a large working dry room—to minimize environmental impact when entering or exiting the room.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cstrong\u003eMobility and Flexibility:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHeight-adjustable\u003cstrong\u003e \u003c\/strong\u003ecasters allow for easy relocation and reorganization (Caster can be purchased or rented). Internal space are dividable for contamination control. \u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cstrong\u003eExtendable:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuffer chambers enable future expansions, supporting multiple connected dry rooms for different applications, such as cathode, anode, electrolyte processing, or cell assembly independently. Interconnect chamber can be customized based on space layout. \u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cstrong\u003eEnhanced Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes viewing doors for visibility and safety, as well as optional no-blind-spot cameras, alarms, smoke detectors, and H2S monitors.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cstrong\u003eOptional Solvent Recycling System:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDepends on dry or wet approach, minimizes chemical exposure, promoting safety and environmental responsibility. Solvent Recycle system can be customized based on specific solvent used. \u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cstrong\u003eUL Compliant:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIf needed,  the system meets UL standards for safety and reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCost-Saving Advantages:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cstrong\u003eReduce planning time:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003etell us your needs by filling out a questionnaire, we will provide the solution for you to approve. Reduce tons of project management time. Significantly reduce labor costs.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cstrong\u003eQuick Startup:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWhen equipment is in, you just need to install two air conducts and two power cords. The plug-and-play design eliminates the need for complex assembly, you can quickly move in your equipment and start operation. \u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cstrong\u003eMinimal Down-time when relocated:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003equick disconnect and reconnect, little down time. Simple carrier loading for moving.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cstrong\u003eEnergy Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNeed-based Individual modular chamber operation saves energy by allowing selective use of specific sections.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cstrong\u003eFuture Expansion:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eModular design supports scalability, helping businesses adapt to growing needs without significant additional investments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eSpecifications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003col\u003e\u003c\/ol\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDry Room Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.192m (L) × 2.438m (W) × 2.896m (H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment Chamber Size*\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.058m (L) × 2.438m (W) × 2.896m (H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperation Area Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.000m (L) × 2.100m (W) × 2.200m (H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDew Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ -50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 ± 2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCleanliness Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110\/220V\/380V\/480V, customizable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50kW for supporting power, 50KW for equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Parameters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTemperature, Dew Point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eViewing Window\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 × 1000mm Double-layer Tempered Glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLighting System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir Shower Room\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSolvent Recovery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eH₂S Treatment Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification of Pipe Joints\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4-NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOther Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSmoke Detector, Security Cameras (2 room diagonal) , Wi-Fi, Equipment status monitoring light\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Operators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne Person (or two)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e*Includes dehumidification system, water cooling system, etc.\u003c\/p\u003e","brand":"Ampcera","offers":[{"title":"Default Title","offer_id":47526809567384,"sku":null,"price":250000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/6987\/2792\/files\/DryRoom_catalog.jpg?v=1764884342"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/6987\/2792\/collections\/DryRoom_catalog.jpg?v=1775047310","url":"https:\/\/www.ampcera.com\/collections\/modular-dryroom.oembed","provider":"Ampcera","version":"1.0","type":"link"}